{"id":1044,"date":"2026-10-12T08:17:30","date_gmt":"2026-10-12T01:17:30","guid":{"rendered":"https:\/\/dutamegaabadi.com\/?post_type=product&#038;p=1044"},"modified":"2026-10-12T08:17:30","modified_gmt":"2026-10-12T01:17:30","slug":"agfa-structurix-d7-rollpack-pb-2","status":"publish","type":"product","link":"https:\/\/dutamegaabadi.com\/?product=agfa-structurix-d7-rollpack-pb-2","title":{"rendered":"Agfa Structurix D7 Rollpack PB"},"content":{"rendered":"<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\">\n<div class=\"content-2s\">\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">X-ray film AGFA D7 Pb Rollpack 100mm x 90m<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The most common X-ray industrial fine grain film among the D-series.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is used by equipment manufacturers as the main one in nomograms for evaluating the performance of X-ray machines.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Those.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">indicators of X-ray machines, which were obtained using D7 film, are taken as a standard.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Package:<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Pb Rollpac is a roll pack with a Pb screen (thickness 0.027 mm), opaque, protected from water and oil and grease.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">No cassettes required, can be cut to any length.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Great for tanks, pipelines and other facilities with en.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">&gt; 100 kV.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Roll length \u2013 90 m, film width \u2013 70 mm \/ 100 mm.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is high-contrast and meets the requirements of class 1 of control sensitivity GOST 7512-82 and the control level of class \u2018B\u2019 GOST ISO 17636-1, corresponds to class C5 film systems according to ISO 11699-1.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">D7 film registers a wide range of radiation intensities, making it possible to obtain contrast images when translucent areas with different thicknesses and intensities, places with a complex configuration, using X-ray machines or gamma radiation.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Purpose \u2013 radiographic control:<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">metals (including non-ferrous)<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">welded and soldered joints, plastics, ceramics, rubber<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">cast components and composites<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">steel objects of small thickness<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Used when:<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Faster film D8 does not provide the desired sensitivity<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Work is underway with pulsed and constant potential x-ray machines, radionuclide sources and accelerators.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Low activity emitters are used and it is necessary to create maximum performance with proper quality (most often everything is used for light metals and thick steel).<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It uses high power x-rays or gamma rays to inspect thick, high-density objects.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Pb intensifying screens help reduce exposure times.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Passes control on multifilm technology when 2+ films are exposed together.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">This is required to cover differences in object thickness or reduce exposure time.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Most often works with Agfa D5 and D4 films.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Properties:<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">high sensitivity, fine grain, high contrast;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">used with many types of x-ray machines;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">removes glare and reflections;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">the exposure coefficient D7 is taken as the standard (relative unit 1.0) among the entire line of films of the AGFA Structurix series;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">the layer does not deteriorate during unpacking, creating a snapshot and during chemical treatments;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">used in both manual and auto development;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">antistatic protection.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Storage conditions:<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">the best storage temperature t = 4\u00b0-24\u00b0C;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">air humidity 50-60%;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">boxes with film must be placed on the edge, away from the chemical.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">reagents;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">radioactive background &lt; 90 nGy\/h;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">at t below 4\u00b0C, there are no irreversible changes in the sensitometric parameters of the film, but after such exposure, boxes with film should be opened after they have warmed up to the operating range (t = 4\u00b0-24\u00b0C).<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Otherwise, moisture condensation is possible, which may cause inhomogeneities and gluing of the film;<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">if properly stored, the manufacturer gives a guarantee for a shelf life of at least 1.5 years.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">It is listed on the packaging.<\/span><\/span><\/span><\/p>\n<p>EXP Date: 2028+<\/p>\n<p>Size: 100mm x 90m<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>X-ray film AGFA D7 Pb Rollpack 100mm x 90m The most common X-ray industrial fine grain film among the D-series. It is used by equipment manufacturers as the main one in nomograms for evaluating the performance of X-ray machines. Those. indicators of X-ray machines, which were obtained using D7 film, are taken as a standard. [&hellip;]<\/p>\n","protected":false},"featured_media":1045,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[70,35],"product_tag":[839,833,834,838,820,805,819,808,837,840,835],"class_list":["post-1044","product","type-product","status-publish","has-post-thumbnail","product_cat-agfa-ndtequipment","product_cat-ndtequipment","product_tag-agfa-industrial-roll-film","product_tag-agfa-structurix-d7-rollpack-pb","product_tag-agfa-structurix-d7-rollpack-pb-for-sale","product_tag-agfa-structurix-d7-rollpack-pb-price","product_tag-industrial-roll-film","product_tag-ndt-equipment","product_tag-ndt-roll-film","product_tag-non-destructive-testing","product_tag-original-agfa-structurix-d7-rollpack-pb","product_tag-pipeline-welding","product_tag-sell-agfa-structurix-d7-rollpack-pb","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=\/wp\/v2\/product\/1044","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1044"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=\/wp\/v2\/media\/1045"}],"wp:attachment":[{"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1044"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=1044"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1044"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dutamegaabadi.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}